9 Be + 16 O, Ecm =16.6 MeV E.Ungricht, D.Balzer, M.Hugi, J.Lang, R.Muller, L.Jarczyk, B.Kamys, A.Strzalkowski,Nuclear Physics, A313 (1979) 376 (access to the source may be restricted by owner!)
CommentsBeam quality: 100 nA Be-9 beam Target: The targets used in the experiments were self-supporting with thicknesses of 150-250 µg/cm2 of SiO2 for O-16. The SiO2 targets were sufficiently pure. Data obtained: exported from EXFOR The experiments were performed at the ETH tandem accelerator in Zurich. Angular resolution was 0.8-1.4 degrees.
Θcm (deg) σ/σR (ratio) error (%) +δσ -δσ 17.23 0.55883 12.362 0.06908 0.06908 20.62 0.54483 15 0.08172 0.08172 24.64 0.3483 15.002 0.05225 0.05225 28.93 0.24423 14.999 0.03663 0.03663 32.59 0.25775 15 0.03866 0.03866 35.74 0.1855 14.998 0.02782 0.02782 37.17 0.16699 15.001 0.02505 0.02505 41.2 0.09863 14.996 0.01479 0.01479 43.71 0.11564 15.004 0.01735 0.01735 48.23 0.1158 15 0.01737 0.01737 51.99 0.06402 14.996 0.0096 0.0096 56.3 0.03782 14.993 0.00567 0.00567 59.92 0.05478 15.006 0.00822 0.00822 63.6 0.05 15 0.0075 0.0075 67.34 0.02992 15.007 0.00449 0.00449 71.32 0.02591 15.014 0.00389 0.00389 74.69 0.02771 15.013 0.00416 0.00416 78.66 0.02529 14.987 0.00379 0.00379 82.43 0.01242 8.777 0.00109 0.00109 85.84 0.01047 8.823 0.00092376 0.00092376 89.17 0.01641 8.837 0.00145 0.00145 92.52 0.02139 11.221 0.0024 0.0024 95.92 0.02086 7.623 0.00159 0.00159 99.09 0.01248 10.017 0.00125 0.00125 101.97 0.00875 11.194 0.00097941 0.00097941 105.02 0.01267 10.024 0.00127 0.00127 108.1 0.01566 15.773 0.00247 0.00247 110.96 0.0122 14.673 0.00179 0.00179 113.22 0.01205 15.768 0.0019 0.0019 116.91 0.01071 15.78 0.00169 0.00169 119.73 0.01086 21.179 0.0023 0.0023 141.96 0.00246 50.814 0.00125 0.00125