Experimental data on
fusion
elastic scattering
evaporation residue

Experimental data on elastic scattering

Specify target and projectile
(at least one item)
Z1 A1   +   Z2 A2    
< Ecm(MeV) <
(Quite recently we started to fill the database. We are very far from finish...)
Show all accumulated data

8Li + 12C,   Elab=23.9 MeV

A.Barioni, V.Guimaraes, A.Lepine-Szily, R.Lichtenthaler, D.R.Mendes Jr, E.Crema, K.C.C.Pires, M.C.Morais, V.Morcelle, P.N.de Faria, R.P.Condori, A.M.Moro, D.S.Monteiro, J.M.B.Shorto, J.Lubian, M.Assuncao,
Physical Review, C80 (2009) 034617
(access to the source may be restricted by owner!)

Comments
Beam quality: The average intensity of the secondary 8Li beam was about 5.0 104 pps.
Target: Polyethylene plastic (CH2) with thickness of 1.6 mg/cm2, mounted together with a thin gold target with thickness of 350 μg/cm2.
Data obtained: exported from EXFOR
Experiment performed at Radioactive Ion Beams in Brazil (RIBRAS) at the University of Sao Paulo. 8Li radioactive beam was produced in a primary 9Be target by the neutron transfer reaction 9Be(7Li,8Li). 

 
Java blocked?

Θcm (deg)dσ/dΩ (mb/sr)error (%)+δσ-δσ
28.27 166 7.531 12.5 12.5
36.54 37.6 7.5 2.82 2.82
47.61 9.2 9.892 0.91 0.91
55.88 2.92 12.227 0.357 0.357
65.04 0.882 18.821 0.166 0.166
78.39 0.0803 183.064 0.147 0.147
86.03 0.0503 59.841 0.0301 0.0301