18O + 174Yb,   Elab=83 MeV

P.K.Sahu, R.K.Choudhury, D.C.Biswas, B.K.Nayak,
Physical Review, C64 (2001) 014609
(access to the source may be restricted by owner!)

Comments
Beam quality: no data
Target: A self-supporting 174-Yb target of thickness 1.2 mg/cm2 was used in the experiment.
Data obtained: exported from EXFOR
The measurements were carried out at the 14 MV BARC-TIFR Pelletron accelerator, Mumbai. 

 
Java blocked?

Θcm (deg)σ/σR (ratio)error (%)+δσ-δσ
59.94 0.942 10 0.0942 0.0942
64.87 0.96 10 0.096 0.096
70.57 1.044 10 0.1044 0.1044
75.88 1.086 10 0.1086 0.1086
81 1.046 10 0.1046 0.1046
91.41 0.89 10 0.089 0.089
101.4 0.584 10 0.0584 0.0584
111.4 0.3312 10 0.0332 0.0332