Show all accumulated data

7Li + 7Li,   Elab=2.5 MeV

E.Norbeck, P.T.Wu, C.R.Chen, R.R.Carlson,
Physical Review, C28 (1983) 1140-1147
(access to the source may be restricted by owner!)

Comments
Beam quality: no data
Target: The targets were made by evapourating isotopically pure (99.99%) LiF (of 10-20 mkg/cm2 thick) onto the thinnest, manageable Formvar films.
Data obtained: author graph (digitized with GSYS 2.4)
The experiment was carried out at the University of Iowa - HVEC Model CN 6 MV Van der Graaff accelerator. The accuracy was estimated in average to be 2 to 3%. 

 
Java blocked?

Θcm (deg)σ/σR (ratio)error (%)+δσ-δσ
50.26 1.0021 0.85 0.0085106 0.0085106
60.2 0.95106 0.895 0.0085106 0.0085106
70.33 0.95106 0.895 0.0085106 0.0085106
80.07 0.92979 0.916 0.0085106 0.0085106
89.8 0.93404 0.912 0.0085106 0.0085106