Experimental data on
fusion
elastic scattering
evaporation residue

Experimental data on elastic scattering

Specify target and projectile
(at least one item)
Z1 A1   +   Z2 A2    
< Ecm(MeV) <
(Quite recently we started to fill the database. We are very far from finish...)
Show all accumulated data

7Li + 7Li,   Elab=2 MeV

E.Norbeck, P.T.Wu, C.R.Chen, R.R.Carlson,
Physical Review, C28 (1983) 1140-1147
(access to the source may be restricted by owner!)

Comments
Beam quality: no data
Target: The targets were made by evapourating isotopically pure (99.99%) LiF (of 10-20 mkg/cm2 thick) onto the thinnest, manageable Formvar films.
Data obtained: author graph (digitized with GSYS 2.4)
The experiment was carried out at the University of Iowa - HVEC Model CN 6 MV Van der Graaff accelerator. The accuracy was estimated in average to be 2 to 3%. 

 
Java blocked?

Θcm (deg)σ/σR (ratio)error (%)+δσ-δσ
60.2 1.0021 0.637 0.006383 0.006383
69.93 0.99149 0.644 0.006383 0.006383
79.87 0.98511 0.864 0.0085106 0.0085106
89.8 0.98298 0.65 0.006383 0.006383