19 F + 208 Pb, Elab =98 MeV C.J. Lin, J.C. Xu, H.Q. Zhang, Z.H. Liu, F. Yang, L.X. Lu,Physical Review, C63 (2001) 064606 (access to the source may be restricted by owner!)
CommentsBeam quality: The beam current range was 100–300 enA. Target: A 208 Pb target of thickness about 100 mg/cm2 evaporated on a 20 mg/cm2 carbon foil backing. Data obtained: author graph (digitized with GSYS 2.4 ) The experiment was carried out at HI-13 tandem accelerator of China Institute of Atomic Energy, Beijing.
Θcm (deg) σ/σR (ratio) error (%) +δσ -δσ 66.63 1 4.962 0.049613 0.049613 70.74 1.0258 3.745 0.03841 0.03841 74.86 1.0793 6.163 0.066515 0.066515 75.89 0.92651 4.962 0.045967 0.045967 78.98 0.97488 3.745 0.036505 0.036505 81.04 1.0389 4.962 0.051543 0.051543 83.1 0.9148 2.513 0.022982 0.022982 87.22 0.9148 3.745 0.034255 0.034255 90.9 1.0128 3.745 0.037925 0.037925 95.17 1.0522 4.962 0.052203 0.052203 95.76 0.93837 6.163 0.057829 0.057829 98.55 1.1071 7.932 0.087815 0.087815 100.5 0.88054 6.163 0.054265 0.054265 100.8 1 6.568 0.065674 0.065674 103.3 1.0389 7.349 0.076347 0.076347 103.3 0.58608 14.158 0.082975 0.082975 103.3 0.7093 12.131 0.086041 0.086041 105 0.76556 7.349 0.05626 0.05626 107.1 0.60118 2.577 0.015492 0.015492 108.6 0.57136 7.349 0.041988 0.041988 110.9 0.52268 9.314 0.04868 0.04868 114.9 0.39009 7.932 0.030941 0.030941 117.5 0.29863 20.467 0.061118 0.061118 119.6 0.26296 22.465 0.059072 0.059072 122.7 0.15809 11.946 0.018884 0.018884 126.2 0.11213 7.349 0.0082403 0.0082403 127.2 0.13399 43.587 0.058402 0.058402 129.2 0.093837 25.368 0.023804 0.023804 130.5 0.077536 8.521 0.0066061 0.0066061 133.6 0.063256 38.334 0.024248 0.024248 133.9 0.036142 22.465 0.008119 0.008119