19 F + 208 Pb, Elab =102 MeV C.J. Lin, J.C. Xu, H.Q. Zhang, Z.H. Liu, F. Yang, L.X. Lu,Physical Review, C63 (2001) 064606 (access to the source may be restricted by owner!)
CommentsBeam quality: The beam current range was 100–300 enA. Target: A 208 Pb target of thickness about 100 mg/cm2 evaporated on a 20 mg/cm2 carbon foil backing. Data obtained: author graph (digitized with GSYS 2.4 ) The experiment was carried out at HI-13 tandem accelerator of China Institute of Atomic Energy, Beijing.
Θcm (deg) σ/σR (ratio) error (%) +δσ -δσ 43.23 1.1506 2.52 0.028986 0.028986 43.23 0.98732 4.975 0.049116 0.049116 45.29 1.0128 3.755 0.038029 0.038029 47.5 1 3.755 0.037547 0.037547 50 1.0128 6.18 0.062585 0.062585 53.97 1.0795 2.585 0.027897 0.027897 54.12 0.91457 4.975 0.045497 0.045497 58.24 1 3.755 0.037547 0.037547 62.51 1.1217 3.902 0.043758 0.043758 62.65 0.97481 6.18 0.060235 0.060235 64.71 1.1217 6.18 0.06931 0.06931 66.63 0.95025 4.975 0.047272 0.047272 70.74 1.0128 6.18 0.062585 0.062585 74.42 0.97481 6.18 0.060235 0.060235 75.16 1.0934 3.902 0.042656 0.042656 78.98 1.1361 4.975 0.056515 0.056515 81.04 0.78476 5.236 0.041083 0.041083 83.1 1.039 4.975 0.051688 0.051688 84.72 1 6.18 0.061792 0.061792 87.22 0.88023 4.975 0.043789 0.043789 90.31 0.68202 2.519 0.01718 0.01718 91.05 0.77481 2.585 0.020022 0.020022 93.26 0.69077 4.975 0.034364 0.034364 95.32 0.52174 4.975 0.025955 0.025955 97.23 0.53522 4.975 0.026625 0.026625 99.14 0.39912 3.755 0.014986 0.014986 100.6 0.31724 9.702 0.030778 0.030778 103.1 0.2757 4.975 0.013715 0.013715 107.1 0.17642 4.975 0.0087761 0.0087761 109.4 0.12824 25.813 0.033102 0.033102 111.1 0.099364 4.975 0.0049431 0.0049431 114.3 0.083113 30.721 0.025533 0.025533 115 0.071316 10.745 0.0076624 0.0076624 118.9 0.043363 9.341 0.0040503 0.0040503 122.7 0.025055 30.721 0.007697 0.007697