4 He + 7 Li, Elab =16 MeV H. G. Bingham, K. W. Kemper, N. R. Fletcher,Nuclear Physics, A175 (1971) 374-384 (access to the source may be restricted by owner!)
CommentsBeam quality: no data Target: The 7 Li used in target preparation was enriched (99.70%) metallic sample. Data obtained: author graph (digitized with GSYS 2.4 ) The elastic scattering measurements were performed using an alpha-particle beam obtained from the Florida State University model EN Tandem Van de Graaff accelerator.
Θcm (deg) dσ/dΩ (mb/sr) error (%) +δσ -δσ 23.7 660.8 7.485 49.46 49.46 28.7 281.2 8.269 23.25 23.25 31.3 64.04 7.966 5.101 5.101 34.8 27.3 7.055 1.926 1.926 39.3 25.47 7.339 1.869 1.869 42.7 36.05 7.185 2.59 2.59 46.4 43.64 7.48 3.264 3.264 50.6 44.48 7.602 3.381 3.381 54.1 40.33 7.122 2.872 2.872 57.9 32.25 6.99 2.254 2.254 62.2 22.29 8.031 1.79 1.79 65.4 21.01 8.04 1.689 1.689 69.5 11.86 7.006 0.8309 0.8309 73.5 11.69 6.696 0.7827 0.7827 76.5 11.38 7.176 0.8166 0.8166 80.4 10.83 7.718 0.8358 0.8358 82.7 9.543 5.971 0.5698 0.5698 87.2 9.647 6.706 0.6469 0.6469 90.3 7.483 7.476 0.5594 0.5594 93.6 5.805 6.989 0.4057 0.4057 96.5 4.466 8.023 0.3583 0.3583 99.7 4.334 6.809 0.2951 0.2951 103 4.085 6.977 0.285 0.285 106 5.455 6.719 0.3665 0.3665 108 6.626 7.477 0.4954 0.4954 112 7.279 7.453 0.5425 0.5425 115 9.083 7.531 0.684 0.684 120 10.04 6.974 0.7001 0.7001 122 11.1 8.043 0.8927 0.8927 125 10.67 7.727 0.8244 0.8244 130 11.15 6.712 0.7483 0.7483 135 10.13 7.481 0.7578 0.7578 140 8.177 7.069 0.578 0.578 145 10.78 7.479 0.8062 0.8062 151 10.38 7.482 0.7766 0.7766 155 14.76 7.494 1.106 1.106 160 22.44 8.044 1.805 1.805