Experimental data on
fusion
elastic scattering
evaporation residue

Experimental data on elastic scattering

Specify target and projectile
(at least one item)
Z1 A1   +   Z2 A2    
< Ecm(MeV) <
(Quite recently we started to fill the database. We are very far from finish...)
Show all accumulated data

7Be + 58Ni,   Elab=19.9 MeV

E. F. Aguilera, E. Martinez-Quiroz, D. Lizcano, A. Gomez-Camacho, J. J. Kolata, L. O. Lamm, V. Guimaraes, R. Lichtenthaler, O. Camargo, F. D. Becchetti, H. Jiang, P. A. DeYoung, P. J. Mears, T. L. Belyaeva,
Physical Review, C79 (2009) 021601(R)
(access to the source may be restricted by owner!)

Comments
Beam quality: Typical secondary beam rates for 7Be of 7.3*104.
Target: An enriched 58Ni target with a thickness of 0.924 mg/cm2 was used for all energies except the lowest one, where the thickness was 0.98 mg/cm2.
Data obtained: author graph (digitized with GSYS 2.4)
A 8B, 7Be, 6Li cocktail beam was produced by the TwinSol radioactive nuclear beam facility at the University of Notre Dame. 

 
Java blocked?

Θcm (deg)σ/σR (ratio)error (%)+δσ-δσ
24.7 1.008 11.935 0.1203 0.1203
27.9 1.008 11.935 0.1203 0.1203
42.2 1.008 12.838 0.1294 0.1294
51.5 1 12.791 0.1279 0.1279
62.5 1.041 12.796 0.1332 0.1332
84.9 0.8513 14.672 0.1249 0.1249
108 0.5511 15.597 0.08595 0.08595
128 0.3292 15.596 0.05134 0.05134