Experimental data on
fusion
elastic scattering
evaporation residue

Experimental data on elastic scattering

Specify target and projectile
(at least one item)
Z1 A1   +   Z2 A2    
< Ecm(MeV) <
(Quite recently we started to fill the database. We are very far from finish...)
Show all accumulated data

8B + 58Ni,   Elab=20.7 MeV

E. F. Aguilera, E. Martinez-Quiroz, D. Lizcano, A. Gomez-Camacho, J. J. Kolata, L. O. Lamm, V. Guimaraes, R. Lichtenthaler, O. Camargo, F. D. Becchetti, H. Jiang, P. A. DeYoung, P. J. Mears, T. L. Belyaeva,
Physical Review, C79 (2009) 021601(R)
(access to the source may be restricted by owner!)

Comments
Beam quality: Typical secondary beam rates for 8B of 4.0*104.
Target: An enriched 58Ni target with a thickness of 0.924 mg/cm2 was used for all energies except the lowest one, where the thickness was 0.98 mg/cm2.
Data obtained: author graph (digitized with GSYS 2.4)
A 8B, 7Be, 6Li cocktail beam was produced by the TwinSol radioactive nuclear beam facility at the University of Notre Dame. 

 
Java blocked?

Θcm (deg)σ/σR (ratio)error (%)+δσ-δσ
26.2 1.017 9.557 0.09719 0.09719
33 1.009 10.328 0.1042 0.1042
42.7 0.9938 10.335 0.1027 0.1027
50 1.021 8.796 0.0898 0.0898
56.8 1.014 7.274 0.07375 0.07375
63.2 0.9988 8.793 0.08782 0.08782
85.9 0.9097 9.561 0.08697 0.08697
109 0.8285 9.56 0.0792 0.0792
129 0.7495 14.277 0.107 0.107
146 0.5572 37.168 0.2071 0.2071