Experimental data on
fusion
elastic scattering
evaporation residue

Experimental data on elastic scattering

Specify target and projectile
(at least one item)
Z1 A1   +   Z2 A2    
< Ecm(MeV) <
(Quite recently we started to fill the database. We are very far from finish...)
Show all accumulated data

12C + 20Ne,   Ecm=48.4 MeV

T. Motobayashi, I. Kohno, T. Ooi, S. Nakajima,
Nuclear Physics, A331 (1979) 193-212
(access to the source may be restricted by owner!)

Comments
Beam quality: no data
Target: For the 20Ne target a cylindrical gas cell 60 mm in diameter was employed.
Data obtained: author graph (digitized with GSYS 2.4)
Beams of the 12C4+ ions accelerated by the Institute of Physical and Chemical Research cyclotron were used 

 
Java blocked?

Θcm (deg)σ/σR (ratio)error (%)+δσ-δσ
13.16 0.4194 6.985 0.029294 0.029294
14.83 0.29201 6.985 0.020396 0.020396
16.32 0.26386 6.985 0.01843 0.01843
18.18 0.24901 6.985 0.017393 0.017393
19.57 0.15441 6.985 0.010785 0.010785
21.06 0.072717 5.628 0.0040925 0.0040925
22.64 0.062009 6.985 0.0043312 0.0043312
24.4 0.085274 6.985 0.0059562 0.0059562
25.89 0.049185 6.985 0.0034354 0.0034354
27.38 0.018108 8.323 0.001507 0.001507
28.87 0.023501 9.078 0.0021333 0.0021333
30.54 0.028369 6.985 0.0019815 0.0019815
32.21 0.018912 6.985 0.001321 0.001321
33.7 0.010597 10.939 0.0011592 0.0011592