6Li + 112Sn,   Elab=25 MeV

N.N. Deshmukh, S. Mukherjee, D. Patel, N.L. Singh, P.K. Rath, B.K. Nayak, D.C. Biswas, S. Santra, E.T. Mirgule, L.S. Danu, Y.K. Gupta, A. Saxena, R.K. Choudhury, R. Kumar, J. Lubian, C.C. Lopes, E.N. Cardozo, P.R.S. Gomes,
Physical Review, C83 (2011) 024607
(access to the source may be restricted by owner!)

Comments
Beam quality: Beam currents ranged between 2.5 and 30 nA.
Target: The 450 and 540 µg/cm2, self-supported enriched 112Sn (99.5%) targets
Data obtained: author graph (digitized with GSYS 2.4)
The experiment was performed at the Bhabha Atomic Research Centre–Tata Institute of Fundamental Research (BARC-TIFR) Pelletron facility, Mumbai, India. 

 
Java blocked?

Θcm (deg)σ/σR (ratio)error (%)+δσ-δσ
31.65 0.9998 5 0.05 0.05
36.76 0.9998 5 0.05 0.05
41.86 0.9998 5 0.05 0.05
47.18 0.9619 5 0.0481 0.0481
52.29 0.9254 5 0.0463 0.0463
57.6 0.9619 5 0.0481 0.0481
62.71 0.9998 5 0.05 0.05
67.82 0.9254 5 0.0463 0.0463
72.92 0.7626 5 0.0382 0.0382
78.03 0.6532 5 0.0327 0.0327
83.14 0.5595 5 0.028 0.028
88.05 0.4611 5 0.0231 0.0231
93.15 0.395 5 0.0198 0.0198
98.26 0.3383 5 0.017 0.017
103.2 0.2483 5 0.0125 0.0125
108.1 0.2127 5 0.0107 0.0107
113 0.156 5 0.0078 0.0078
117.9 0.1389 5 0.007 0.007
122.8 0.1237 5 0.0062 0.0062
127.7 0.09435 7.4478 0.0071 0.0071
132.4 0.08733 8.04649 0.0071 0.0071
137.1 0.07196 7.44858 0.0054 0.0054
142 0.0666 12.31081 0.0082 0.0082
146.9 0.05489 7.44762 0.0041 0.0041
151.8 0.0508 10.96063 0.0056 0.0056
161.2 0.04186 14.34066 0.0061 0.0061
170.6 0.04887 10.96174 0.0054 0.0054