(Quite recently we started to fill the database. We are very far from finish...)
Show all accumulated data
6Li + 90Zr, Elab=29.93 MeV
H. Kumawat, V. Jha, B. J. Roy, V. V. Parkar, S. Santra, V. Kumar, D. Dutta, P. Shukla, L. M. Pant, A. K. Mohanty, R. K. Choudhury, S. Kailas, Physical Review, C78 (2008) 044617
(access to the source may be restricted by owner!)
Comments
Beam quality: Beam currents were typically in the range of 5–30 nA. Target: 400 μg/cm2, self-supported enriched 90Zr (≥99%) target. Data obtained: author graph (digitized with GSYS 2.4)Experimental measurements were performed using the 6Li(3+) beam delivered by the 14UD Pelletron accelerator of the TIFR/BARC Facility in Mumbai, India. The elastically scattered 6Li ions were detected by four solid state silicon surface barrier detectors in a ΔE + E telescopic arrangement.