7 Li + 12 C, Elab =5.8 MeV J.E. Poling, E. Norbeck, R.R. Carlson,Physical Review, C5 (1972) 1819-1825 (access to the source may be restricted by owner!)
CommentsBeam quality: no data Target: Carbon sef-supporting foils from 5 to 50 μg/cm2 thick. Data obtained: author graph (digitized with GSYS 2.4 ) Measurements were made at the University of Iowa Van de Graaff accelerator.
Θcm (deg) σ/σR (ratio) error (%) +δσ -δσ 23.39 0.9791 3.448 0.03375 0.03375 27.67 0.9914 3.402 0.03372 0.03372 30.76 1.011 3.095 0.03129 0.03129 33.16 0.9723 3.467 0.0337 0.0337 38.4 0.975 3.955 0.03856 0.03856 42.92 0.9849 3.672 0.03616 0.03616 46.76 0.9176 4.462 0.04094 0.04094 54.64 0.8722 5.25 0.04579 0.04579 61.56 0.8532 5.653 0.04823 0.04823 68.98 0.7837 4.612 0.03614 0.03614 77.11 0.7069 4.087 0.02889 0.02889 83.79 0.6856 5.976 0.04097 0.04097 90.01 0.6377 4.91 0.03131 0.03131 96.92 0.626 5.387 0.03372 0.03372 102.9 0.5612 4.721 0.02649 0.02649 109.3 0.5398 5.806 0.03134 0.03134 115.1 0.5425 5.77 0.0313 0.0313 121.5 0.5283 7.299 0.03856 0.03856 127 0.5358 6.301 0.03376 0.03376 131.3 0.4685 7.2 0.03373 0.03373 135.1 0.4687 6.166 0.0289 0.0289 139.4 0.44 7.116 0.03131 0.03131 143 0.4474 7.54 0.03373 0.03373 147.1 0.4018 8.99 0.03612 0.03612 149.9 0.4429 7.077 0.03134 0.03134