6 Li + 209 Bi, Elab =32 MeV S. Santra, S. Kailas, K. Ramachandran, V. V. Parkar, V. Jha, B. J. Roy, P. Shukla,Physical Review, C83 (2011) 034616 (access to the source may be restricted by owner!)
CommentsBeam quality: no data Target: The selfsupporting target (209 Bi), with a thickness of ∼330 μg/cm2 , was prepared by the vacuum evaporation technique. Data obtained: author graph (digitized with GSYS 2.4 ) The experiment was performed using a 6 Li beam from the BARC-TIFR 14-UD pelletron facility in Mumbai.
Θcm (deg) σ/σR (ratio) error (%) +δσ -δσ 61.45 0.9974 9.664 0.09638 0.09638 66.58 0.9968 11.176 0.1114 0.1114 71.7 0.9962 12.669 0.1262 0.1262 76.56 1.013 9.65 0.09775 0.09775 81.68 0.995 9.666 0.09617 0.09617 86.81 0.9451 9.663 0.09132 0.09132 91.93 0.8533 9.659 0.08242 0.08242 96.78 0.797 11.176 0.08907 0.08907 99.75 0.732 11.171 0.08177 0.08177 101.6 0.7075 9.663 0.06836 0.06836 106.8 0.6496 11.178 0.07261 0.07261 110 0.6069 10.693 0.06489 0.06489 111.6 0.5481 11.186 0.06131 0.06131 116.7 0.5119 11.175 0.0572 0.0572 119.4 0.4321 11.169 0.04826 0.04826 121.3 0.432 9.667 0.04176 0.04176 126.7 0.3644 9.657 0.03519 0.03519 129.7 0.3347 11.172 0.03739 0.03739 131.3 0.2973 9.657 0.02871 0.02871 136.4 0.2921 12.664 0.03699 0.03699 139.1 0.2465 11.177 0.02755 0.02755 141.3 0.2549 9.663 0.02463 0.02463 146.1 0.2188 12.665 0.02771 0.02771 148.8 0.2079 11.174 0.02323 0.02323 151 0.2043 8.126 0.0166 0.0166 155.8 0.1754 11.175 0.0196 0.0196 160.7 0.1666 12.672 0.02111 0.02111 165.5 0.153 9.661 0.01478 0.01478 170.6 0.1478 8.823 0.01304 0.01304