Experimental data on
fusion
elastic scattering
evaporation residue

Experimental data on elastic scattering

Specify target and projectile
(at least one item)
Z1 A1   +   Z2 A2    
< Ecm(MeV) <
(Quite recently we started to fill the database. We are very far from finish...)
Show all accumulated data

6Li + 209Bi,   Elab=50 MeV

S. Santra, S. Kailas, K. Ramachandran, V. V. Parkar, V. Jha, B. J. Roy, P. Shukla,
Physical Review, C83 (2011) 034616
(access to the source may be restricted by owner!)

Comments
Beam quality: no data
Target: The selfsupporting target (209Bi), with a thickness of ∼330 μg/cm2, was prepared by the vacuum evaporation technique.
Data obtained: author graph (digitized with GSYS 2.4)
The experiment was performed using a 6Li beam from the BARC-TIFR 14-UD pelletron facility in Mumbai.  

 
Java blocked?

Θcm (deg)σ/σR (ratio)error (%)+δσ-δσ
23.12 0.9996 15.087 0.1508 0.1508
26.11 1.041 15.092 0.1571 0.1571
28.6 0.9395 15.083 0.1417 0.1417
31.1 1.129 20.187 0.2279 0.2279
33.84 1.152 18.49 0.213 0.213
36.33 1.275 15.091 0.1924 0.1924
38.82 0.9976 15.077 0.1504 0.1504
41.31 0.9973 18.47 0.1842 0.1842
43.8 0.7644 16.798 0.1284 0.1284
46.54 0.6623 13.324 0.08824 0.08824
49.28 0.4774 15.078 0.07198 0.07198
51.52 0.4053 16.795 0.06807 0.06807
54 0.3302 16.802 0.05548 0.05548
56.74 0.2149 22.681 0.04874 0.04874
61.96 0.1187 18.484 0.02194 0.02194
64.2 0.105 15.086 0.01584 0.01584
66.68 0.06976 18.478 0.01289 0.01289
71.66 0.03625 16.798 0.006089 0.006089
76.88 0.01845 18.488 0.003411 0.003411
81.85 0.01129 16.812 0.001898 0.001898
87.08 0.008306 16.796 0.001395 0.001395
96.79 0.004313 18.496 0.0007977 0.0007977