Experimental data on
fusion
elastic scattering
evaporation residue

Experimental data on elastic scattering

Specify target and projectile
(at least one item)
Z1 A1   +   Z2 A2    
< Ecm(MeV) <
(Quite recently we started to fill the database. We are very far from finish...)
Show all accumulated data

7Li + 16O,   Elab=36 MeV

P. SCHUMACHER, N. UETA, H.H. DUHM, K.-I. KUBO, W. J. KLAGES,
Nuclear Physics, A212 (1973) 573-599
(access to the source may be restricted by owner!)

Comments
Beam quality: The average current on the target was not more than about 100 nA Li(3+) on the target (maximum beam intensity ~500 nA)
Target: The 12C, 13C, 26Mg and 28Si16O2 targets were made by conventional vacuum evaporation techniques.
Data obtained: author graph (digitized with GSYS 2.4)
The experiments were performed at the Heidelberg MP Tandem Van de Graaff accelerator.  

 
Java blocked?

Θcm (deg)dσ/dΩ (mb/sr)error (%)+δσ-δσ
14.46 2125 8.97 190.6 190.6
18.57 768.6 10.687 82.14 82.14
21.71 342 10.699 36.59 36.59
24.34 123.8 8.999 11.14 11.14
24.81 91.6 8.993 8.237 8.237
25.5 52.1 12.308 6.412 6.412
27.97 51.07 10.655 5.441 5.441
29.46 53.99 10.677 5.764 5.764
30.67 40.7 10.666 4.341 4.341
34.58 24.45 12.352 3.02 3.02
35.49 10.49 10.677 1.12 1.12
38.62 3.868 10.665 0.4125 0.4125
40.58 3.084 9.868 0.3043 0.3043
45.06 4.316 23.147 0.999 0.999
48.94 2.031 10.685 0.217 0.217
50.61 0.939 10.671 0.1002 0.1002
52.23 0.2871 8.98 0.02578 0.02578
54.96 0.3209 13.996 0.04491 0.04491
55.98 0.476 10.687 0.05087 0.05087
58.25 0.7607 8.98 0.06831 0.06831
59.19 0.4245 10.677 0.04532 0.04532
62.55 0.1347 10.661 0.01436 0.01436
66.04 0.1958 12.34 0.02416 0.02416
69.02 0.2272 12.338 0.02803 0.02803