4He + 233UH. Delagrange, A. Fleury, J.M. Alexander, Physical Review, C17 (1978) 1706-1720
(access to the source may be restricted by owner!) CommentsBeam quality: no information Target: 0.2-0.8g/cm2, 99.3 % 233U Detected particles: radiochemical method Data obtained: author's table |
|
1n 2n 3n All channels | 3nElab (MeV) | σ (mb) | +δσ | -δσ | 28.9 | 0.0522 | 0.0051 | 0.0051 | 30.3 | 0.252 | 0.01 | 0.01 | 30.9 | 0.209 | 0.063 | 0.063 | 31.9 | 0.378 | 0.027 | 0.027 | 31.9 | 0.489 | 0.045 | 0.045 | 32.7 | 1.209 | 0.032 | 0.032 | 33.7 | 2.05 | 0.14 | 0.14 | 33.8 | 1.47 | 0.11 | 0.11 | 33.8 | 1.75 | 0.14 | 0.14 | 34.1 | 1.446 | 0.056 | 0.056 | 35.1 | 1.418 | 0.091 | 0.091 | 35.6 | 1.07 | 0.1 | 0.1 | 36.9 | 1.442 | 0.056 | 0.056 | 37.1 | 0.984 | 0.045 | 0.045 | 37.4 | 1.06 | 0.043 | 0.043 | 37.4 | 0.736 | 0.06 | 0.06 | 38.2 | 0.93 | 0.076 | 0.076 | 39 | 0.476 | 0.048 | 0.048 | 39 | 0.744 | 0.024 | 0.024 | 39.1 | 0.896 | 0.034 | 0.034 | 39.5 | 0.672 | 0.098 | 0.098 | 40.4 | 0.66 | 0.31 | 0.31 |
|