12C + 12CD. G. Kovar, D. F. Geesaman, T. H. Braid et al., Physical Review, C 20 (1979) 1305
(access to the source may be restricted by owner!) CommentsBeam quality: no data Target: 12C: 20-40 mcg/cm^2, self-supporting foil Detected particles: EvR Data obtained: author's table Argonne National Laboratory (ANL) FN tandem accelerator; relative errors are listed, absolute errors are 5% or 10% |
|
| Ecm (MeV) | σ (mb) | +δσ | -δσ | 7.44 | 286 | 20 | 20 | 8.7 | 392 | 20 | 20 | 9.32 | 551 | 20 | 20 | 9.95 | 577 | 17 | 17 | 10.58 | 587 | 25 | 25 | 11.2 | 594 | 18 | 18 | 11.83 | 670 | 25 | 25 | 12.46 | 701 | 22 | 22 | 13.08 | 740 | 25 | 25 | 13.71 | 747 | 24 | 24 | 14.33 | 859 | 30 | 30 | 14.96 | 856 | 21 | 21 | 15 | 838 | 25 | 25 | 15.59 | 875 | 30 | 30 | 16.21 | 843 | 22 | 22 | 16.84 | 861 | 28 | 28 | 17.46 | 855 | 25 | 25 | 18.09 | 844 | 26 | 26 | 18.72 | 867 | 22 | 22 | 19.34 | 907 | 26 | 26 | 19.97 | 906 | 22 | 22 | 20.59 | 956 | 29 | 29 | 21.22 | 935 | 21 | 21 | 21.84 | 917 | 28 | 28 | 22.47 | 874 | 23 | 23 | 23.09 | 843 | 25 | 25 | 23.72 | 862 | 21 | 21 | 24.35 | 832 | 25 | 25 | 24.97 | 878 | 24 | 24 | 25.6 | 879 | 25 | 25 | 26.22 | 868 | 23 | 23 | 26.85 | 835 | 30 | 30 | 27.47 | 834 | 22 | 22 | 28.72 | 766 | 20 | 20 | 29.98 | 726 | 21 | 21 | 31.23 | 716 | 26 | 26 |
|