27Al + 70GeE.F. Aguilera, J.J. Vega, J.J. Kolata et al., Physical Review, C 41 (1990) 910
(access to the source may be restricted by owner!) CommentsBeam quality: no data Target: 1) 70Ge (96.75%): (86+-9) mcg/cm^2; carbon backing 20 mcg/cm^2; 2) 70Ge (84.62%): (587+-23) mcg/cm^2 Detected particles: EvR Data obtained: author's table Three-stage tandem Van de Graaff facility at University of Notre Dame |
|
| Ecm (MeV) | σ (mb) | +δσ | -δσ | 50.2 | 0.48 | 0.13 | 0.13 | 50.9 | 1.16 | 0.19 | 0.19 | 51.2 | 1.44 | 0.17 | 0.17 | 51.6 | 3.12 | 0.35 | 0.35 | 51.9 | 4.78 | 0.34 | 0.34 | 52.3 | 7.47 | 0.73 | 0.73 | 52.6 | 8.31 | 0.5 | 0.5 | 53 | 13.4 | 1.3 | 1.3 | 53.3 | 16.83 | 0.86 | 0.86 | 53.9 | 28 | 1.2 | 1.2 | 54.5 | 47.6 | 2 | 2 | 55.1 | 62.4 | 2.4 | 2.4 | 55.8 | 89.1 | 3.3 | 3.3 | 56.4 | 98.6 | 3 | 3 | 57.1 | 134.6 | 4.3 | 4.3 | 57.8 | 160.8 | 5.4 | 5.4 | 58.5 | 181.1 | 5.9 | 5.9 | 59.2 | 224 | 6.8 | 6.8 | 59.2 | 220.6 | 8.2 | 8.2 | 59.9 | 267.8 | 8.4 | 8.4 | 59.9 | 255.1 | 9.3 | 9.3 |
|