32S + 64NiA.M. Stefanini, G. Fortuna, R. Pengo et al., Nuclear Physics, A 456 (1986) 509
(access to the source may be restricted by owner!) CommentsBeam quality: 100 keV Target: 64Ni (96.5%): 265 mcg/cm^2 Detected particles: EvR Data obtained: author's table XTU Tandem accelerator at Laboratori Nazionali di Legnaro |
|
| Ecm (MeV) | σ (mb) | +δσ | -δσ | 52.74 | 0.046 | 0.016 | 0.016 | 53 | 0.059 | 0.02 | 0.02 | 53.34 | 0.099 | 0.03 | 0.03 | 53.66 | 0.199 | 0.066 | 0.066 | 54 | 0.232 | 0.067 | 0.067 | 54.34 | 0.64 | 0.17 | 0.17 | 54.68 | 1.13 | 0.29 | 0.29 | 54.99 | 1.78 | 0.45 | 0.45 | 55.6 | 3.86 | 0.97 | 0.97 | 56.21 | 9.12 | 2.3 | 2.3 | 56.81 | 16.38 | 4.8 | 4.8 | 57.43 | 28.29 | 7.5 | 7.5 | 57.65 | 32.54 | 8.3 | 8.3 | 58 | 34.46 | 7 | 7 | 58.64 | 52.6 | 13 | 13 | 59.25 | 64.08 | 13 | 13 | 60.55 | 101.8 | 22 | 22 | 61.68 | 140.5 | 30 | 30 | 63.18 | 186.9 | 38 | 38 | 64.46 | 203.8 | 41 | 41 | 65.83 | 290.1 | 58 | 58 | 67.15 | 353.7 | 71 | 71 | 68.44 | 362.9 | 72 | 72 | 71.11 | 457.7 | 92 | 92 | 73.77 | 506.9 | 100 | 100 | 76.43 | 588.3 | 120 | 120 | 79.1 | 598.5 | 120 | 120 | 85.77 | 602.2 | 120 | 120 | 89.76 | 698.5 | 140 | 140 | 100.43 | 750.7 | 152 | 152 |
|