34S + 25MgG. M. Berkowitz, P. Braun-Munzinger, J. S. Karp et al., Physical Review, C 28 (1983) 667
(access to the source may be restricted by owner!) CommentsBeam quality: no data Target: 25Mg (>98%): 50-200 mcg/cm^2; carbon backing 10 mcg/cm^2 Detected particles: EvR Data obtained: author's graph Stony Brook FN Tandem Van de Graaff accelerator |
|
| Ecm (MeV) | σ (mb) | +δσ | -δσ | 24.81 | 0.58425 | 0.13067 | 0.13067 | 25.25 | 1.9712 | 0.25973 | 0.25973 | 25.69 | 4.3094 | 0.47221 | 0.47221 | 26.12 | 9.9086 | 0.99626 | 0.99626 | 26.56 | 19.288 | 1.9393 | 1.9393 | 26.96 | 32.434 | 3.2611 | 3.2611 | 27.38 | 54.542 | 5.4839 | 5.4839 | 27.81 | 87.204 | 8.7679 | 8.7679 | 28.24 | 105.64 | 11.099 | 11.099 | 28.65 | 141.55 | 15.823 | 15.823 | 29.08 | 172.34 | 18.884 | 18.884 | 29.53 | 192.57 | 19.362 | 19.362 | 29.93 | 229.77 | 23.103 | 23.103 | 30.35 | 229.77 | 23.103 | 23.103 | 30.57 | 261.98 | 28.707 | 28.707 | 30.8 | 282.58 | 30.965 | 30.965 | 31.21 | 295.71 | 31.401 | 31.401 | 31.65 | 344.04 | 37.699 | 37.699 | 32.03 | 386.38 | 38.849 | 38.849 |
|