46Ti + 46TiA.M. Stefanini, M. Trotta, L. Corradi et al., Physical Review, C 65 (2002) 34609
(access to the source may be restricted by owner!) CommentsBeam quality: no data Target: 46Ti (96.84%): 50 mcg/cm^2; carbon backing: 15 mcg/cm^2 Detected particles: EvR Data obtained: author's table XTU Tandem accelerator at Laboratori Nazionali di Legnaro of Istituto Nazionale di Fisica Nucleare |
|
| Ecm (MeV) | σ (mb) | +δσ | -δσ | 58 | 0.45 | 0.15 | 0.15 | 58.5 | 0.56 | 0.14 | 0.14 | 59 | 1.77 | 0.27 | 0.27 | 59.5 | 3.24 | 0.27 | 0.27 | 60 | 5.33 | 0.45 | 0.45 | 60.5 | 9.06 | 0.49 | 0.49 | 61 | 12.74 | 0.52 | 0.52 | 61.5 | 21.22 | 0.65 | 0.65 | 62 | 29.25 | 1.06 | 1.06 | 62.5 | 39.9 | 1.2 | 1.2 | 63 | 43.6 | 2.1 | 2.1 | 63.5 | 62.7 | 1.6 | 1.6 | 64 | 80.7 | 2.1 | 2.1 | 64.5 | 93.3 | 2.1 | 2.1 | 65 | 113.5 | 2.1 | 2.1 | 65.5 | 141.4 | 2.4 | 2.4 | 66 | 159.5 | 2.3 | 2.3 | 66.5 | 171.8 | 3.5 | 3.5 | 67 | 216 | 4.4 | 4.4 | 67.5 | 227.9 | 3 | 3 | 68 | 273.6 | 3.2 | 3.2 | 68.5 | 297 | 3.3 | 3.3 | 69 | 329 | 3.6 | 3.6 | 69.5 | 338.6 | 3.8 | 3.8 | 70 | 342.6 | 4.3 | 4.3 | 70.5 | 383.5 | 4.4 | 4.4 | 71 | 372.4 | 5.7 | 5.7 |
|