58Ni + 60NiA.M. Stefanini, D. Ackermann, L. Corradi et al., Physical Review Letters, 74 (1995) 864
(access to the source may be restricted by owner!) CommentsBeam quality: 0.125% Target: 60Ni (99.8%): 100 mcg/cm^2; carbon 20 mcg/cm^2 Detected particles: EvR Data obtained: author's table XTU Tandem accelerator at Laboratori Nazionali di Legnaro; quoted errors include statistical errors only, overall error in vertical scale is +-15% |
|
| Ecm (MeV) | σ (mb) | +δσ | -δσ | 91.606 | 0.040319 | 0.0048383 | 0.0048383 | 92.622 | 0.28022 | 0.015926 | 0.015926 | 93.14 | 0.71164 | 0.075599 | 0.075599 | 93.618 | 1.4082 | 0.099992 | 0.099992 | 94.096 | 2.8395 | 0.11189 | 0.11189 | 94.564 | 3.6761 | 0.13608 | 0.13608 | 95.022 | 5.8826 | 0.26409 | 0.26409 | 95.51 | 6.939 | 0.27619 | 0.27619 | 96.008 | 10.171 | 0.30239 | 0.30239 | 96.506 | 12.721 | 0.26208 | 0.26208 | 97.004 | 16.954 | 0.53222 | 0.53222 | 97.512 | 18.607 | 0.64108 | 0.64108 | 98.02 | 24.978 | 0.60277 | 0.60277 | 98.518 | 30.703 | 0.73684 | 0.73684 | 99.016 | 34.211 | 0.74792 | 0.74792 | 99.524 | 43.363 | 0.8457 | 0.8457 | 100.02 | 55.6 | 3.6892 | 3.6892 | 100.53 | 62.566 | 2.6308 | 2.6308 | 101.53 | 75.508 | 1.7539 | 1.7539 | 102.53 | 91.454 | 2.268 | 2.268 | 103.56 | 112.72 | 1.9555 | 1.9555 | 104.71 | 125.34 | 2.3688 | 2.3688 | 105.57 | 155.91 | 3.7295 | 3.7295 | 106.59 | 187.45 | 5.1206 | 5.1206 | 107.77 | 206.65 | 7.1869 | 7.1869 | 108.6 | 225.49 | 6.5116 | 6.5116 | 109.61 | 239.14 | 2.4897 | 2.4897 | 110.62 | 259.43 | 6.824 | 6.824 | 111.64 | 272.64 | 4.4049 | 4.4049 | 113.67 | 307.64 | 8.2352 | 8.2352 | 115.69 | 323.13 | 9.3037 | 9.3037 | 117.72 | 336.24 | 11.924 | 11.924 | 119.24 | 364.76 | 14.848 | 14.848 |
|