4He + 197AuH.E. Kurz, E.W. Jasper, K. Fischer, F. Hermes, Nuclear Physics, A168 (1971) 129-138
(access to the source may be restricted by owner!) CommentsBeam quality: external 104+-0.5 MeV 4He beam Target: foils with 20 or 40 mg/cm2 Detected particles: gamma-rays of EvR Data obtained: author's table Karlsruhe Isochronous Cyclotron. The experimental error in the cross sections has been estimated to be less than 10 %. The uncertainty of 0.5 MeV in the incident energy and smaller uncertainties in the thickness of the foils result in less then +- 1 MeV errors in the energy at the end of the thick foil stacks. |
|
1n 2n 3n 4n 5n 6n 7n 8n 1p3n All channels | 3nElab (MeV) | σ (mb) | +δσ | -δσ | 29.5 | 131 | 0 | 0 | 32.9 | 546 | 0 | 0 | 36.1 | 918 | 0 | 0 | 39.1 | 1071 | 0 | 0 | 42 | 870 | 0 | 0 | 47.4 | 410 | 0 | 0 | 52.4 | 231 | 0 | 0 | 61.5 | 130 | 0 | 0 | 1p3nElab (MeV) | σ (mb) | +δσ | -δσ | 39.1 | 1.6 | 0 | 0 | 42 | 3.2 | 0 | 0 | 44.8 | 6.7 | 0 | 0 | 49.9 | 23.1 | 0 | 0 | 59.3 | 58.9 | 0 | 0 | 67.8 | 66.2 | 0 | 0 | 77.4 | 63.1 | 0 | 0 | 86.2 | 52.6 | 0 | 0 |
|